Performance Analysis of Steam Power Plants Using Ideal Reheat-Rankin Cycle.pdf
Journal: International Journal of Advanced engineering, Management and Science (Vol.3, No. 4)Publication Date: 2017-04-22
Authors : Fawaz Sultan;
Page : 305-312
Keywords : Reheat temperature; Condenser weight; Boiler weight; Reheat-Rankin cycle proficiency.;
Abstract
In this paper, a hypothetical examination has been done to assess the execution of the power plants that are chipping away at Reheat-Rankin cycle. The execution of cycle was dissected for various (warm, evaporator, condenser weights) values and also warm temperature qualities to demonstrate its impact on cycle warm proficiency. In this work, the heater weights qualities was accepted limited between (10to 26 MPa), the pressure proportion (warm stage weight to evaporator weight) was expected fluctuated in wide range from (0.1 to 1.0), while the condenser weight was accepted shifted between (5 to 25 kPa). And, a variety in warm temperature esteem was done between scopes of (400-600oC) at low weight turbine. The outcomes demonstrate that the warm productivity is considerably upgraded when the pressure proportion lies between (0.25-0.35) and the ideal proficiency is gotten when the pressure proportion and evaporator weight are equivalent to( 0.33 and 26MPa) separately .
Other Latest Articles
- Compressive Strength of Concrete Containing Milled Glass as Partial Substitute for Cement.pdf
- Free cashflow and firm performance.pdf
- Study and Analysis of HySi Data in 400 to 500.pdf
- PROBLEMS OF DEVELOPMENT OF INNOVATIVE ACTIVITY IN THE AIC OF THE CHUVASH REPUBLIC
- INFORMATION STRUCTURE OF CONSTRUCTION ELEMENT IN RUSSIAN BIM DATABASE
Last modified: 2017-04-23 04:18:04