STUDY OF GROUND PORK THAWING DYNAMICS USING MAGNETIC RESONANCE IMAGING
Journal: Theory and practice of meat processing (Vol.4, No. 1)Publication Date: 2019-03-30
Authors : Vladimir М. Stefanovskiy Evgeny V. Morozov Vyacheslav M. Bоuznik;
Page : 17-20
Keywords : thawing; ground pork; research method; magnetic resonance imaging;
Abstract
Visualization of changes in shape and size of the frozen residue during the thawing of ground pork is implemented using magnetic resonance imaging. A technique has been developed to study the displacement of thawing front line without damage to integrity of the object being thawed. It has been established that the melting of bound water crystals outran the melting of free water crystals in meat. A mathematical model that adequately describes the experimental data obtained in the analysis of tomograms is proposed. Tomograms are an important information source for studying the patterns of heat and mass transfer during the thawing of frozen foods.
Other Latest Articles
- CLIMATE CHANGE: IMPACT ON MYCOTOXINS INCIDENCE AND FOOD SAFETY
- THE INFLUENCE OF IONIZING RADIATION ON THE THERMOPHYSICAL PROPERTIES OF MEAT FROM THE BROILER CHICKENS WITH DIFFERENT STRESS RESISTANCE
- THE DEVELOPMENT OF MARKETING IN TOURISM INDUSTRY
- THE OPINIONS AND PREFERENCES OF THE EUROPEAN BUYERS ON THE FURNITURE AND FURNITURE ACCESSORIES MARKET
- APPROACHES TO STAFF BEHAVIOUR FROM THE PERSPECTIVE OF OPERATIONS MANAGEMENT
Last modified: 2019-04-17 23:51:15