INVESTIGATION OF HYDRAULIC PERFORMANCE OF A FLAP TYPE CHECK VALVE USING CFD AND EXPERIMENTAL TECHNIQUE

Journal: International Journal of Mechanical Engineering and Technology(IJMET) (Vol.10, No. 1)

Publication Date:

Authors : ; ;

Page : 409-413

Keywords : Check valve; CFD; Loss coefficient; pressure drop; Disc angle; valve size; valve seat; experiment; Turbulence model;

Source : Downloadexternal Find it from : Google Scholarexternal

Abstract

An attempt has been made to simulate flow through an 820 check valve by using CFD. with different flow velocities. The pressure drops ( (V) are used to determine t obtained analytical values of “K The computational analysis has been carried out at five different disc angles of check valve i.e. for 54° (fully opened), 46°, 34°, 24°, 10°. The pressure drops ( pressure loss coefficient (K experimental values. The obtained numerical results are in close agreement with experimental values, for higher design is modeled and tested in the laboratory which has shown a 10% of pressure loss in the valve.