Abstract
The article discusses hydraulic carrying capacity design method for horizontal pipe drainage, consisting of separate corrugated plastic pipes, laid in the existing ones [1]. Calculations are carried out for pipes with diameters D=63, 75, 90, 110 mm, discharge characteristic K is estimated, K=f(D) relationship graph is drawn. Water section area, discharge characteristics, silting and actual velocity, water discharge as pipe filling function is calculated for the chosen diameter 110mm.