CEMENT 222Rn and 226Ra CONCENTRATION MEASUREMENTS IN SELECTED SAMPLES FROM DIFFERENT COMPANIES
Journal: Asian Journal of Natural and Applied Sciences (Vol.2, No. 4)Publication Date: 2013-12-15
Authors : Ali K. Alsaedi; B.A. Almayahi; A.H. Alasadi;
Page : 94-99
Keywords : cement; Radon; CR-39; exhalation rate;
Abstract
Solid-state nuclear track detectors (CR-39) are widely used for radon exhalation rate measurements in cement under different conditions. The detectors were exposed to standard radon concentration from a standard 226Ra source. A calibration factor of 0.0107 track cm-2 per Bq d m-3 was determined. The 222Rn and 226Ra concentrations varied from 18Bq m-3 to 178 Bq m-3 and 0.09 Bq kg-1 to 1.30 Bq kg-1, respectively. The highest radon exhalation rate was found in Sulaymanyah, Iraq
Other Latest Articles
- VAGINAL BIRTH AFTER CAESAREAN SECTION(VBAC) A TWO YEAR COMPARATIVE REVIEW OF OUTCOME AT ABUBAKAR TAFAWA BALEWA UNIVERSITY TEACHING HOSPITAL BAUCHI NIGERIA
- EFFECTS OF HEAD INJURY ON MEMORY
- ANTIBACTERIAL ACTIVITY OF NIGELLA SATIVA AND PIPER NIGRUM
- PERFORMANCE AND EMISSION CHARACTERISTICS OF COMPRESSION IGNITION ENGINES USING BIODIESEL AS A FUEL: A REVIEW
- IMPACT OF FEEDING SELECTED MULBERRY GERMPLASM VARIETIES ON SILKWORM BOMBYX MORI L. THROUGH BIOASSAY TECHNIQUES FOR COMMERCIAL EXPLOITATION
Last modified: 2014-11-09 02:54:26