CHEST COMPRESSION METHODS IN SIMULATED COVID-19 PATIENT RESUSCITATION: A RANDOMIZED CROSS-OVERSIMULATION TRIAL
Journal: Journal of the Grodno State Medical University (Vol.18, No. 6)Publication Date: 2020-12-31
Authors : Evrin T.; Bielski K.; Dabrowska A.; Smereka J.; Ladny J. R.; Malysz M.; Yakubtsevich R.; Szarpak L.;
Page : 669-675
Keywords : chest compression; cardiopulmonary resuscitation; quality; feedback device; TrueCPR; personal protective equipment; COVID-19; SARS-CoV-2; medical simulation;
Abstract
Background: High-quality chest compression is one of the key elements of resuscitation to return of spontaneous circulation. In the COVID-19 era, medical personnel should wear personal protective equipment (PPE) against aerosol generating procedures (AGP) during resuscitation. However, the use of this personal protection equipment may reduce the effectiveness of medical procedures performed. Objective: We aimed to compare chest compression quality parameters between standard manual chest compression and chest compression with TrueCPR feedback device performed by medical students wearing full personal protractive equipment against aerosol generating procedure.Methods: The study was designed as a randomized, cross-over, single-blinded simulation study. Thirty-two medical students wearing PPE-AGP performed 2-min continuous chest compression on an adult simulator with and without TrueCPR feedback device.Results: Median chest compression depth with and without TrueCPR feedback device varied and amounted to 46 (IQR; 42-53) vs. 41 (IQR; 36-45) mm (MCC vs. TrueCPR, respectively). The manual chest compression rate was 117 (IQR; 112-125) compressions per minute (CPM) and was higher than with TrueCPR feedback device - 107 (IQR; 102-115; p = 0.017). Full chest relaxation in the manual's chest compression technique (without TrueCPR) was 33 (IQR; 26-42)% and was lower than with chest compression with TrueCPR feedback device - 58 (IQR; 40-75)% (p=0.002). Conclusions: We conclude that a TrueCPR feedback device improves chest compression quality during simulated COVID-19 resuscitation performed by medical students wearing PPE-AGP.
Other Latest Articles
- WEIGHING EMPLOYEE INNOVATIVE PERFORMANCE WITHIN THE CONTEXT OF INTEGRATED RETENTION SYSTEM
- THE ROLE OF IMMUNOFLUORESCENCE IN DIAGNOSIS AND PROGNOSIS OF GLOMERULOPATHIES WITH EXTRACAPILLARY PROLIFERATION
- PERCUTANEOUS CORONARY INTERVENTIONS – CURRENT STATE OF DEVELOPMENT: PREVENTION OF COMPLICATIONS AND FUTURE PERSPECTIVES
- MARKETING TO CHILDREN: DEVELOPING AND VALIDATING A SCALE TO MEASURE ASSOCIATED PARENTAL CONCERNS
- MITOCHONDRIAL ATP SYNTHASE
Last modified: 2021-01-26 16:11:16