ResearchBib Share Your Research, Maximize Your Social Impacts
Sign for Notice Everyday Sign up >> Login

MEASUREMENT OF INDUSTRIAL SEWING NEEDLE TEMPERATURE WITH DIFFERENT EXPERIMENTAL TECHNIQUES

Journal: International Journal of Textile and Fashion Technology (IJTFT) (Vol.11, No. 2)

Publication Date:

Authors : ; ;

Page : 1-10

Keywords : Needle Temperature; Thermal Camera; Thermocouple; Pyrometer & Sewing Thread;

Source : Downloadexternal Find it from : Google Scholarexternal

Abstract

This article is about measuring sewing needle temperatures with three different methods (thermal camera, pyrometer, and implanted thermocouple) on an industrial lockstitch machine. The needle temperature test was performed for a cumulative period of 60 seconds at varying system speeds from 1500 rpm to 4500 rpm. The results of the experimental techniques are compared at various speeds of sewing. This article will be functional in respect of verification with experimental results for investigators who use theoretical models in sewing needle temperature measurement. Results represent when using thread, needle temperature is still higher than when no thread is used that contradicts the findings of some investigators who consider the thread as a heat sinker.

Last modified: 2022-01-22 20:27:21