Protection of building materials from biodeterioration
Journal: Вестник МГСУ / Vestnik MGSU (Vol.17, No. 02)Publication Date: 2022-02-28
Authors : Popikhina Elena A.; Trepova Ekaterina S.; Khazova Svetlana S.;
Page : 178-187
Keywords : biocide; antiseptic; biodeterioration of building materials; effectiveness of biocides against fungi; resistance of fungi; fungicidal effect;
Abstract
Introduction. The foci of biological damage can lead to destruction of building materials. The paper presents the results of an examination of samples of brickwork and cladding of an industrial building with traces of biological damage. Materials and methods. The contamination of materials was identified using the Koch method. The effectiveness of biocides was evaluated using the disk diffusion method, namely, its modification applied to identify the fungicidal activity by adding antiseptics to samples of damaged building materials, identifying the number of viable microorganisms in the material, processing damaged building structures and monitoring the microorganisms on their surfaces. Results. The number of viable microorganisms in the studied samples of building materials exceeded the acceptable value, which evidences the process of biodegradation. The resistance of isolated strains of fungi to biocides, that have various derivatives of isothiazolone as the main active ingredient, was determined. Conclusions. Sanatex, Macrosept, Rocima GT, Rocima 243, Neomid 440 Eco can be recommended for the disinfection treatment of biologically damaged building materials.
Other Latest Articles
- The impact of religious tourism on the quality of the urban transport system in the historical city
- Assessment of the spatial development of areas adjacent to urban railway stations
- A field study on effects of openings on thermal performance of natural cooling efficiency for atrium buildings
- A scenario-and-network approach to the urban planning development of the Abakan-Yenisei settlement system
- Justification of the optimal base choice for the anti-filtration circuit during the reclamation of toxic waste storage facilities