ResearchBib Share Your Research, Maximize Your Social Impacts
Sign for Notice Everyday Sign up >> Login

Development of a Multichannel Analyzer for Radioactive Isotopes Detection

Journal: International Journal of Trend in Scientific Research and Development (Vol.6, No. 3)

Publication Date:

Authors : ;

Page : 1823-1828

Keywords : radar; Spectrum; near-field measurement; radiation pattern;

Source : Downloadexternal Find it from : Google Scholarexternal

Abstract

This report is a summary of work carried out at Defence Laboratory DRDO Jodhpur during internship as a part of Masters of Computer Application. The report is the brief description of study about the Multichannel Analyzer and crystallization of work. The work helps in developing insight on a state of the robust technology MCA to identify radioisotopes during the nuclear emergency. Study of Multichannel Analyzer is in the way that it would be able to store the spectrum that is to be displayed. Ferventness of MCA spectrum is classified further in two parts respectively which are Energy spectrum that is Calibrated and Pulse Height spectrum which is non calibrated. A new approach to problem solving is in the direction of feasible survey, and in addition to this requires a remarkably low down time by measuring the spectrum pattern on site in nuclear emergency. The solution is the so called near field spectrum pattern measurement method, which requires mathematical parameters and algorithms. Hemant Singh Rajpurohit | Prof. Bhuvana J "Development of a Multichannel Analyzer for Radioactive Isotopes Detection" Published in International Journal of Trend in Scientific Research and Development (ijtsrd), ISSN: 2456-6470, Volume-6 | Issue-3 , April 2022, URL: https://www.ijtsrd.com/papers/ijtsrd49790.pdf Paper URL: https://www.ijtsrd.com/computer-science/computer-network/49790/development-of-a-multichannel-analyzer-for-radioactive-isotopes-detection/hemant-singh-rajpurohit

Last modified: 2022-07-20 18:54:17