Comparative Analysis and Design of Multistory Reinforced Concrete SMRF and OMRF Buildings in Seismic Zone II
Journal: International Journal of Science and Research (IJSR) (Vol.11, No. 5)Publication Date: 2022-05-05
Authors : Prasanna Pradip Kanoje; Hrashvardhan Rangari; Girish Sawai;
Page : 1956-1964
Keywords : SMRF; OMRF; Story drift; Earthquakes;
Abstract
The present work has been performed on G+ 15 story OMRF & SMRF Symmetrical Building for seismic zone II as per IS 1893:2002 (Part I). Building has been Modelled Analysed in ETABS & design Calculations & optimizations are done in RCDC. Structure Modelled is having 6 Bays of 4m & 1 bay of 5m along 29m side & 4 Bays of 4m & 2 Bays of 3m along 22m side. Amount of steel required, Story drift, story Displacements, lateral loads, story stiffness, story moments are taken as Parameters of comparison.