Investigation of Fresh Concrete for Quality Control Purpose Using Resistivity Probe Method
Journal: International Journal for Innovative Research in Science and Technology (Vol.2, No. 7)Publication Date: 2015-2016
Authors : Neha Yadav;
Page : 77-81
Keywords : Water-Cement Ratio; Electrical Resistivity; Fresh Concrete; Resistivity Probe & Quality Control;
Abstract
The water cement ratio in any cement-based material imparts a very important role. The determination of water cement ratio for quality control of fresh concrete, a new method has been developed named as “Electrical Resistivity”. This method isn?t very much popular because not much work has been done yet. In the present work a total number of 3 mixes has been prepared, three w/c ratio?s (0.4 ,0.5 & 0.6 ) has been taken. The water content is kept same during whole work (186kg/m3) as per IS 456:2000 guidelines. It is found that the resistivity of fresh concrete has a strong direct correlation with w/c. The resistivity probe used to measure the w/c is found within ±0.01 of the actual value for all the mixtures tested.
Other Latest Articles
- Environment sanitation and Building design
- Approximate solution of the MHD boundary layer flow pasta moving continuous flat surface using quartic Spline
- An Experimental Investigation on Strength Characteristic of High Density Concrete incorporating hematite
- Synthesis, Structure-Parameter Correlation And Biological Evaluation Of 1-(2-Chloro-5-Nitrophenyl)-3-Phenyl-2-Propenone Compounds
- State of the art of technologies for Zn2+ ions removal from industrial effluents with adsorption: Examination of process parameters (Part I)
Last modified: 2016-01-05 18:58:42