THE NEW STRUCTURE OF A PLATE-PILE FOUNDATION
Journal: Bulletin of Prydniprovs'ka State Academy of Civil Engineering and Architecture (Vol.2016, No. 1)Publication Date: 2016-04-04
Authors : SAMORODOV О. V.;
Page : 58-65
Keywords : plate; pile; plate-pile foundation; pressure; deformation; piles’s length; piles’s step;
Abstract
In the construction of high-rise buildings with significant loads on foundations and bedding at the base of not rocky soils tend to use the most common pile foundation to reduce the deformation and correspond to regulations [1] on the maximum permissible deformation. Monitoring of the stress-strain state (SSS) pile foundations constructed buildings shows the existing reserves of bearing capacity on the one hand - soil bases of the second group of limit states, on the other - the foundation of the first group of limit states by regulating the SSS foundation during construction and exploitation. Therefore, are increasingly using more progressive structure of foundations consisting of piles and of plate, as well as methods for their construction [2 - 10], however, in their design there are a number of disadvantages associated with the ambiguity of the application of methods for the calculation of such structures, which allows to do only partial conclusions and recommendations. Purpose. Is proposing the new structure of a plate-pile foundation, which overcomes the drawbacks of the existing design solutions and methods of consruction their, as well as is proposing an engineering method of a determination of basic parameters. Conclusion. Is proposes the new structure of a plate-pile foundation and the method of a determination of basic parameters his in the design of a soil base to the maximum permissible deformation Su buildings. Efficiency of application this type plate-pile foundation obtained by rational distribution resistance between a plate and piles, when under load from the building to the first work fully incorporated plate that allows maximum deformed for plate, and then the piles - due to of the hinge connection with the plate. Thus, depending on the maximum permissible deformation for buildings resistance of plate part of a full load of more than 50%, that significantly reduces the consumption of concrete.
Other Latest Articles
- THE MATHEMATICAL BASIS FOR THE THEORY OF JOINT WORK OF THE FOUNDATION AND THE FOUNDATION WITH THE ?ARCH” EFFECT
- ALGORITHM FOR SEARCH OF END TIME OF THE COMPLEX PROJECT
- DEFINITION OF DENSITY OF THE THERMAL STATIONARY STREAMS ON A SURFACES OF A SLEEVE OF CYLINDER INTERNAL COMBUSTION ENGINE BY A METHOD OF OPTIMUM FILTRATION KALMANA
- EXTEND OPERATION PROBLEMS AND RECONSTRUCTION OF LARGE-PANEL FIVE-STOREY BUILDINGS OF 50-60-IES XX CENTURY
- FROM THE POLYTECHNIC INSTITUTE TO THE CONSTRUCTION ACADEMY
Last modified: 2016-04-04 18:36:25