Mass and Energy Balance in Grate Cooler of Cement Plant
Journal: International Journal of Scientific Engineering and Technology (IJSET) (Vol.2, No. 7)Publication Date: 2013-07-01
Authors : Raziuddin Ahmad Tasmeem Ahmad Khan Vedika Agarwal;
Page : 631-637
Keywords : solid temperature; wall temperature and heat losses;
Abstract
Objective of this paper is development of first principle based model of grate cooler for cement plant. In this work, the temperature variation and assumptions of the model will be discussed. The model is developed for steady state condition. Variations of gas, solid temperature, wall temperature and heat losses through the wall are simulated with respect to grate cooler length. The model is validated by comparing the output with the published experimental simulation data and by observing the response to step changes. Step changes are used for validation and to understand the influence of various design and operating parameters on grate cooler performance
Other Latest Articles
- Comparative Performance Analysis of Insert Geometry for Turning Operation on CNC Turning Centre
- Performance of 3-Phase Neutral Point Clamped Active Front End Multilevel Converter
- COSDES of Junk E-Mail with Junk Free System Scheme
- Study on the Effect of Forming Parameters in Sheet Hydrodynamic Deep Drawing Using FEM-based Taguchi Method
Last modified: 2013-09-03 19:02:01