ResearchBib Share Your Research, Maximize Your Social Impacts
Sign for Notice Everyday Sign up >> Login

A comparative evaluation of implantation of intra-ocular lens by Push ? In method versus Pull ? In method.

Journal: JOURNAL OF MEDICAL EDUCATION AND RESEARCH (Vol.2, No. 1)

Publication Date:

Authors : ; ;

Page : 8-11

Keywords : Intra-ocular lens; push-in; pull-in.;

Source : Download Find it from : Google Scholarexternal

Abstract

ABSTRACT Purpose: To compare outcomes of implantation of intra-ocular lens (IOL) by push ? in and pull ? in; in accordance of, in the bag placement of IOL, anterior chamber maintenance, stretching of incision and chances of infection creeping into anterior chamber. Methods: Two hundred thirty cataract cases were selected for IOL implantation, one hundred fifteen by each method. The details of findings of number of attempts taken by each method for implanting IOL in bag and problems noted with each method were recorded. Results: Pull ? in method of IOL implantation was found to be more beneficial than Push ? in method, with former having advantage of higher incidence of, in the bag implantation with a significance of 98% (Chi-square test probability value less than .02) less anterior chamber collapse, less instrumentation and less wound gaping with only disadvantage of a confident hand required for pull?in method. Conclusion: Pull-in method is better than push-in method with advantages of its own.

Last modified: 2013-09-20 15:33:44