Abstract
A Power quality problem is an occurrence manifested as a nonstandard voltage, current or frequency that results in a failure or a mis-operation of end user equipment’s. Utility distribution networks, sensitive industrial loads and critical commercial operations suffer from various types of outages and service interruptions which can cost significant financial losses. With the restructuring of power systems and with shifting trend towards distributed and dispersed generation, the issue of power quality is going to take newer dimensions. Injection of the wind power into an electric grid affects the power quality. The performance of the wind turbine and thereby power quality are determined on the basis of measurements and the norms followed according to the guideline specified in International Electro-technical Commission standard, IEC-61400. The influence of the wind turbine in the grid system concerning the power quality measurements are-the active power, reactive power, variation of voltage, flicker, harmonics, and electrical behavior of switching operation and these are measured according to national/international guidelines. Static Compensator (STATCOM) is connected at a point of common coupling with a battery energy storage system (BESS) to mitigate the power quality issues. The battery energy storage is integrated to sustain the real power source under fluctuating wind power. Here two control schemes for STATCOM are Fuzzy logic controller and hybrid Fuzzy logic controller. We can better response for hybrid fuzzy compare to fuzzy logic controller. The STATCOM control scheme for the grid connected wind energy generation system for power quality improvement is simulated using MATLAB/SIMULINK in power system block set. Finally the proposed scheme is applied for both balanced and unbalanced linear nonlinear loads.
Other Latest Articles
- Experimental Investigation of High ? Strength Characteristics of Self Curing Concrete
- Emerging Trends in Recruitment Process Outsourcing
- Note on Co Ideals in Ternary Semigroups
- A Survey on Cryptographic Algorithms for Secured Communication
- SYNTHESIS AND EVALUATION OF ANTI-CORROSIVE BEHAVIOR OF SOME SCHIFF BASE DERIVATIVE
Last modified: 2016-07-15 09:59:35