Concurrent and countercurrent flow mode comparison in the tube in tube heat exchanger
Journal: Scientific review, Науковий огляд, Научное обозрение (Vol.28, No. 7)Publication Date: 2016-09-02
Authors : Lucheyko I. D.; Kotsiurko R.V.;
Page : 15-26
Keywords : temperature field; number of transfer units; water equivalent simplex; indicator of heat transfer efficiency; mathematical modeling;
Abstract
The “pipe in pipe” heat exchanger efficiency at concurrent and countercurrent flow mode analytical studied. It is established that at concurrent flow mode with increasing of water equivalent simplex temperature difference on the output decreases and at countercurrent flow mode it increases. Performance indicator with convenient limits , which allow to assess the degree of heat transfer from the hot to the cold coolant, is introduced. It is established that there is a maximum along for temperature difference on the tube space outlet at concurrent and countercurrent flow modes. At sufficiently small and large values of water equivalent simplexes the difference between the flow modes is practically omited.
Other Latest Articles
- Formation of structural elements of millet harvest, depending on the variety, sowing date and fertilizing
- The essence and characteristics of communicative-speech development of younger students
- Intellectuality in formation culture professional future communication jornalist (high school)
- On the problem of professional training of future teachers of economy
- Study of fundamental physical concepts using the symmetry properties based on physical and computer modeling in higher education technical profile
Last modified: 2016-09-02 04:06:04