Resistance to heat transfer three-layer concrete panels
Journal: Construction, materials science, mechanical engineering (Vol.1, No. 82)Publication Date: 2016-11-10
Authors : Bolshakov V.I.; Sopilnyak A.M.; Iurchenko Iev.L.; Panchenko M.V.;
Page : 50-54
Keywords : three-layer reinforced concrete wall panel; resistance to heat transfer;
Abstract
Raising of problem. In construction there are different kinds of three-layer reinforced concrete cladding wall panels.The middle layer of these panels is a materials of heat-insulation (mineral wool, polymer, lightweight concrete), which have high thermal properties. The calculations were performed on the thermal conductivity using the software package Elcut 5" for main types of walling mass application in the construction of buildings for various purposes. Purpose. Analysis results of calculations of a heat transfer resistance for some designs of three-layer reinforced concrete wall panels for mass application. Conclusion. The resistance of heat transfer panels with flexible links and panels with monolithic links between the layers and the middle layer of polystyrene on 1.35...2.1 higher than other variants structures. For the first temperature zone the minimum value of the resistance of heat transfer provides for panels with flexible links and the middle layer of expanded polystyrene (450...500 mm), extruded polystyrene foam (450...500 mm), and mineral wool (500 mm). And panels with monolithic links between the layers and the middle layer of polystyrene concrete (450...500 mm). For the second temperature zone the minimum value of thermal resistance of enclosing structures of residential and public buildings provide panels with flexible links and the middle layer of polystyrene (400...500 mm ), extruded polystyrene foam (400...500 mm), mineral wool (450...500 mm), and panels with monolithic links between the layers and the middle layer of polystyrene (400...500 mm).
Other Latest Articles
- The influence of direction of the nodal load on stability of the von Mises truss with elastic supports on the example of ribbed domes with rings of steel
- Feasibility of the algorithmic optimization of multistory buildings with steel frame
- Reduction factor for buckling of central-compressed steel elements considering initial geometrical imperfections and residual stresses
- Meet the challenges of the protection of employees of the special division in extreme situations by heat exposure
- Accounting risks factors of appearance accident situations during exploitation of buildings
Last modified: 2016-11-10 00:26:59