CARBON DIOXIDE EXTINGUISHING OF FIRE IN VERTICAL STEEL TANKS WITH OIL AND OIL PRODUCTS
Journal: Pozharovzryvobezopastnost/Fire and Explosion Safety (Vol.22, No. 3)Publication Date: 2013-03-30
Authors : MERKULOV Vladimir Artemovich Candidate of Technical Sciences KUZMENKO Konstantin Petrovich Candidate of Technical Sciences KIRSANOV Artem Igorevich Foreman ZAO ARTSOK;
Page : 58-61
Keywords : vertical steel tank; carbon dioxide; automatic extinguishing plant; fire safety.;
Abstract
Object of your work is experimental research of possibilities and application conditions of automatic gas-extinguishing plant on base of isotermic gas fire extinguishing modules for liquid carbon dioxide (MIZU) intended for fire protection in vertical steel tanks with oil. Work represents results of full-scale fire test of fire extinguishing with carbon dioxide in vertical steel tank with partly dismantled roof (volume 2000 m3 ) filled with diesel oil. Gas-extinguishing plant consist of MIZU volume 16 m3 connected with distributional loop pipeline Du 80 mm, mounted on tank's upper chord, by main pipeline Du 150 mm 82 m long. Eight spray nozzles for carbon dioxide supply mounted on distributional pipeline were adaxial placed into tank. On the grounds of existing literary information and requirements of regulations it was anticipatorily assumed that for fire extinguishing in tank it is necessary to supply no less then 13 kg of carbon dioxide to 1 m3 surface of burning oil product. Two tests were done, during first test time of diesel oil free combustion was taken as 126 seconds, and during second test — 142 seconds. Received information after test — automatic gas-extinguishing plant on base of MIZU is capable to supply fire extinguishing on fire starting stage in tank with support of taken feeding rate of ÑÎ2 13 kgm2 in time no more then 60 seconds. Received data were confirmed by series of analogous natural tests of fire extinguishing in tank (volume 5000 m3 ) with completely dismantled roof which didn't reveal Scaled influence of vessel's area on taken feeding rate of ÑÎ2 to 1 m2 area of burning oil product.
Other Latest Articles
- THE STUDY OF FIRE SAFETY PROVISION FOR PEOPLE WITH SEEING, HEARING AND MOVING DISABILITIES
- ON MODEL UNCERTAINTY OF FIRE RISK OF GROUND TANK WITH GASOLINE
- PASSIVE FIRE PROTECTION OF WOODEN CONSTRUCTIONS OF CHURCÍES DOMES WITH APPLICATION OF IMPREGNATING COMPOUNDS
- INFLUENCE OF EXTERNAL STORAGE CONDITIONS OF VODKA ON ITS FIRE AND EXPLOSIVE HAZARD CHARACTERISTICS
- CONDITIONS AND CHARACTERISTICS OF SHREDDED COAL IGNITION WITH LOCAL HEATING
Last modified: 2019-10-24 01:49:02